GMW14700
Note: Nothing in this standard supercedes
applicable laws and regulations.
Note: In the event of conflict between the
English and domestic language, the English language shall take
precedence.
Purpose. This standard describes the test
procedures to evaluate the stone impact resistance of coatings. It
is applicable to both coated metallic and coated composite panels.
Method A is a contained method where the gravelometer is contained
in a constant temperature freezer and Method B is the transfer
method where test panels are transferred from a freezer to the
gravelometer at room temperature. Method C is a contained method
where the gravelometer is contained in a constant temperature room.
If this standard is used on uncoated panels (e.g., molded-in-color
(MIC) plastic), alternate evaluation and rating procedures will be
required.
Method A: A cold room or freezer of sufficient
size in which the gravelometer and the test samples can be
maintained at -18 °C ± 2 °C.
Method B: A freezer in which the test samples
can be cooled to the test temperature of -18 °C ± 2 °C.
Preconditioning that causes frost on the surface of the test
specimens must be avoided.
Method C: A room in which the gravelometer and
the test samples can be maintained at 22 °C ± 5 °C.
Foreword. Not applicable.
Applicability. Not applicable.